Check icon

Success

Your request has been successfully submitted.

Shut Off Valves

Kromschroeder VAN magnetic relief valves

For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved

Kromschroeder VAN magnetic relief valves_1
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC Proof of closure switch for 24 V and visual position indicator, left side Electrical connection: M20 cable gland Accessories, right: 2 screw plugs Accessories, left: 2 screw plugs
Name
Description
File size
Operating Instructions for VAN Magnetic relief valve
755.44 KB
Technical Information for VAN magnetic relief valve, in english, GB 3 Edition 05.17
1.52 MB
Image
SKU
Description
88012134
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012135
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012136
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88012144
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC E
88012137
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88012145
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88012138
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88012146
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012139
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88012147
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012154
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012140
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88012155
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012148
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88012141
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88012156
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC E
88012149
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88012142
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012157
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88012150
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88012164
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88012143
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012165
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88012151
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88012158
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012174
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88012184
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 200 V
88012166
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012159
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012152
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88012175
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88012185
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') NPT internal thread Quick opening, quick closing Mains voltage: 12
88012167
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012160
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88012153
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88012176
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88012186
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 100 V
88012161
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88012194
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 25 (1'') Outlet: DN 25 (1'') NPT internal thread Quick opening, quick closing Mains voltage: 120 V
88012187
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 100 V AC,
88012168
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC P
88012195
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') NPT internal thread Quick opening, quick closing Mains voltage
88012162
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88012188
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88012196
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') NPT internal thread Quick opening, quick closing Mains voltage: 12
88012189
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 200 V
88012169
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88012163
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88012229
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012197
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') NPT internal thread Quick opening, quick closing Mains voltage: 12
88012177
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88012230
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012190
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 200 V AC,
88012170
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012198
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 25 (1'') Outlet: DN 25 (1'') NPT internal thread Quick opening, quick closing Mains voltage: 120 V
88012178
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012231
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012171
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012191
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88012199
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') NPT internal thread Quick opening, quick closing Mains voltage
88012179
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012192
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 100 V AC,
88012172
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88012180
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC P
88012193
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') NPT internal thread Quick opening, quick closing Mains voltage: 12
88012173
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88012181
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88012182
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 100 V
88012243
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') No outlet flange Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88012183
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012235
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012236
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012237
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012238
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC E
88012239
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC E
88012307
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88012299
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88012402
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012437
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') NPT internal thread Quick opening, quick closing Mains voltage
88012404
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012461
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') NPT internal thread Quick opening, quick closing Mains voltage
88012373
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88012487
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012452
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88012453
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88012454
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88012455
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88012456
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') NPT internal thread Quick opening, quick closing Mains voltage
88012457
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') NPT internal thread Quick opening, quick closing Mains voltage: 12
88012458
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') NPT internal thread Quick opening, quick closing Mains voltage: 12
88012507
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012459
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 25 (1'') Outlet: DN 25 (1'') NPT internal thread Quick opening, quick closing Mains voltage: 120 V
88012493
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88012460
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') NPT internal thread Quick opening, quick closing Mains voltage
88012528
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012529
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC P
88012720
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012721
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012639
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 25 (1'') Outlet: DN 25 (1'') NPT internal thread Quick opening, quick closing Mains voltage: 120 V
88012640
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') NPT internal thread Quick opening, quick closing Mains voltage: 12
88012774
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012779
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC P
88012780
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88012781
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88012785
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88012786
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88012887
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC P
88012852
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012905
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88012908
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012895
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88012954
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88013050
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88013132
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88013210
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88013261
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88013211
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88013188
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88013367
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88013484
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88013394
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 24 V DC Proof of closure switch fo
88013525
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88013526
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88013463
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 120 V AC, 50/60 Hz Proof of clos
88013405
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88013584
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC Pr
88013585
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88013481
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88013504
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88013574
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 25 (1'') Outlet: DN 25 (1'') NPT internal thread Quick opening, quick closing Mains voltage: 230 V
88013594
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88013576
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88013654
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified No inlet flange No outlet flange Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC, 50/60
88013699
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') NPT internal thread Quick opening, quick closing Mains voltage
88013700
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 50 (2'') Outlet: DN 50 (2'') NPT internal thread Quick opening, quick closing Mains voltage: 120 V
88013656
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88013701
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') NPT internal thread Quick opening, quick closing Mains voltage
88013582
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC Pr
88013677
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88013805
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88013696
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88013775
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88013652
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified No inlet flange No outlet flange Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC, 50/60
88013697
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88013698
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88013865
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88013866
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 230 V AC, 50/60 Hz Electrical conn
88013876
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88013877
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88013851
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC E
88014045
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') NPT internal thread Quick opening, quick closing Mains voltage: 12
88014046
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 50 (2'') Outlet: DN 50 (2'') NPT internal thread Quick opening, quick closing Mains voltage: 120 V
88014021
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC E
88013929
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88014047
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') NPT internal thread Quick opening, quick closing Mains voltage: 12
88013930
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') NPT internal thread Quick opening, quick closing Mains voltage: 12
88014048
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 50 (2'') Outlet: DN 50 (2'') NPT internal thread Quick opening, quick closing Mains voltage: 120 V
88014067
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88013948
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') NPT internal thread Quick opening, quick closing Mains voltage: 12
88014039
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 120 V AC, 50/60 Hz Proof of clos
88013990
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88014072
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88014127
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88014162
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88014232
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 120 V AC, 50/60 Hz Accessories,
88014108
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88014109
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88014312
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') NPT internal thread Quick opening, quick closing Mains voltage: 24
88014351
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 50 (2'') Outlet: DN 50 (2'') NPT internal thread Quick opening, quick closing Mains voltage: 120 V
88014242
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 25 (1'') Outlet: DN 25 (1'') NPT internal thread Quick opening, quick closing Mains voltage: 24 V D
88014359
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88014360
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88014401
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC P
88014635
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88014715
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88015084
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 25 (1'') Outlet: DN 25 (1'') NPT internal thread Quick opening, quick closing Mains voltage: 24 V D
88015097
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88015257
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') NPT internal thread Quick opening, quick closing Mains voltage: 23
88015258
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') NPT internal thread Quick opening, quick closing Mains voltage: 23
88015259
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 25 (1'') Outlet: DN 25 (1'') NPT internal thread Quick opening, quick closing Mains voltage: 230 V
88015327
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88015477
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88015478
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88015479
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88015480
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88015333
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88015334
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88015546
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88015548
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88015398
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88015549
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88015472
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88015473
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88015474
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88015475
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC E
88015476
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88015654
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88015554
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88015512
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88015613
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88015692
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') NPT internal thread Quick opening, quick closing Mains voltage
88015693
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') NPT internal thread Quick opening, quick closing Mains voltage
88015678
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88015744
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange No outlet flange Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC, 50/60
88015683
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88015745
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange No outlet flange Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC, 50/60
88015653
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88015706
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88015599
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88015824
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88015922
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88015950
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 25 (1'') Outlet: DN 25 (1'') NPT internal thread Quick opening, quick closing Mains voltage: 24 V D
88016020
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88016108
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') NPT internal thread Quick opening, quick closing Mains voltage: 24
88016067
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC E
88016122
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88016218
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88016464
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC E
88016554
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88016555
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88016637
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Flange to ISO 7005 Quick opening, quick closing Mains voltage: 2
88016532
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC P
88016716
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88016749
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88016769
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88016659
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88016916
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 25 (1'') Outlet: DN 25 (1'') NPT internal thread Quick opening, quick closing Mains voltage: 120 V
88016930
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 230 V AC, 50/60 Hz Proof of clos
88016980
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88016931
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 230 V AC, 50/60 Hz Proof of clos
88016838
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88016936
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC E
88016954
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 100 V
88017120
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC P
88017107
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') NPT internal thread Quick opening, quick closing Mains voltage: 24
88017342
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88017546
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88017451
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC P
88017435
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88017491
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88017731
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Flange to ISO 7005 Quick opening, quick closing Mains voltage: 2
88017708
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88017678
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88017903
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88017927
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88017928
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88017929
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88018033
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88018119
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88018424
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 50 (2'') Outlet: DN 50 (2'') NPT internal thread Quick opening, quick closing Mains voltage: 24 V D
88018494
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') NPT internal thread Quick opening, quick closing Mains voltage
88018495
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 50 (2'') Outlet: DN 50 (2'') NPT internal thread Quick opening, quick closing Mains voltage: 24 V D
88018579
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') NPT internal thread Quick opening, quick closing Mains voltage: 24
88018834
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88018899
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88019104
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88019291
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88019409
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC Pr
88019576
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') NPT internal thread Quick opening, quick closing Mains voltage
88019714
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88019753
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88019585
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88019811
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88019819
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') NPT internal thread Quick opening, quick closing Mains voltage: 24
88019750
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88020227
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC P
88020442
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') No outlet flange Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC, 50
88020512
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 24 V DC Electrical connection: M20
88020959
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88021176
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88021419
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88021421
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88021186
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88021823
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 25 (1'') Outlet: DN 25 (1'') NPT internal thread Quick opening, quick closing Mains voltage: 230 V
88022222
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') NPT internal thread Quick opening, quick closing Mains voltage: 23
88021965
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88023593
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC E
88023980
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC P
88024009
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC P
88023965
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88023966
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88024024
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88024117
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') NPT internal thread Quick opening, quick closing Mains voltage: 23
88024484
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88024860
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') NPT internal thread Quick opening, quick closing Mains voltage
88024811
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88024959
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88025033
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88024926
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88024927
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88024928
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88025016
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88025175
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88025208
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V A
88025305
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88025823
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88026322
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC, 50
88026325
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88026663
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed No inlet flange Outlet: DN 15 (1/2'') NPT internal thread Quick opening, quick closing Mains voltage: 24 V DC
88026670
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed No inlet flange Outlet: DN 15 (1/2'') NPT internal thread Quick opening, quick closing Mains voltage: 230 V A
88026945
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 24 V DC Electrical connection: plu
88026812
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88027052
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88027177
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 25 (1'') Outlet: DN 25 (1'') NPT internal thread Quick opening, quick closing Mains voltage: 24 V D
88027239
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88027221
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') NPT internal thread Quick opening, quick closing Mains voltage: 24
88027424
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88027455
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88028046
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88028047
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88028048
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88028049
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88028050
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88028144
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC P
88028122
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 230 V AC, 50/60 Hz Electrical conn
88028297
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') NPT internal thread Quick opening, quick closing Mains voltage: 24
88028420
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 230 V AC, 50/60 Hz Electrical conn
88029489
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88029495
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88029861
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88029862
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88029834
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC P
88030705
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 120 V AC, 50/60 Hz Accessories,
88030706
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 25 (1'') Outlet: DN 25 (1'') NPT internal thread Quick opening, quick closing Mains voltage: 120 V
88030713
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88030827
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88030828
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88030792
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88030868
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88030837
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') NPT internal thread Quick opening, quick closing Mains voltage: 12
88030838
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88030849
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88031060
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 120 V AC, 50/60 Hz Proof of clos
88031170
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88031164
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88031217
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88031609
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC E
88031636
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88031761
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Flange to ISO 7005 Quick opening, quick closing Mains voltage: 1
88031781
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 50 (2'') Outlet: DN 50 (2'') NPT internal thread Quick opening, quick closing Mains voltage: 230 V
88031800
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 100 V
88031824
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88031853
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88032041
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88032089
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88032090
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88032116
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 230 V AC, 50/60 Hz Proof of closur
88032096
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88032277
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 24 V DC Proof of closure switch fo
88032278
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 230 V AC, 50/60 Hz Proof of closur
88032279
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 24 V DC Proof of closure switch fo
88032280
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 230 V AC, 50/60 Hz Proof of closur
88032308
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 230 V AC, 50/60 Hz Electrical conn
88032341
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88032345
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 120 V AC, 50/60 Hz Proof of closur
88032346
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 120 V AC, 50/60 Hz Proof of closur
88032401
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88032363
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88032364
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') NPT internal thread Quick opening, quick closing Mains voltage
88032528
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 32 (1 1/4'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88032557
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88032546
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 2
88033008
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V DC
88033020
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 50 (2'') Outlet: DN 50 (2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V AC,
88033021
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 120 V AC, 50/60 Hz Proof of clos
88033022
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 24 V DC Accessories, right: 2 sc
88033115
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 120 V AC, 50/60 Hz Proof of clos
88033116
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 120 V AC, 50/60 Hz Proof of clos
88033117
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 120 V AC, 50/60 Hz Proof of clos
88033118
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed No inlet flange No outlet flange Quick opening, quick closing Mains voltage: 120 V AC, 50/60 Hz Proof of clos
88033119
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 EU certified Inlet: DN 40 (1 1/2'') Outlet: DN 32 (1 1/4'') Rp internal thread Quick opening, quick closing Mains voltage: 1
88033235
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88033253
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') NPT internal thread Quick opening, quick closing Mains voltage: 12
88033234
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 25 (1'') Outlet: DN 25 (1'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V AC,
88033351
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 10 (3/8'') Outlet: DN 10 (3/8'') Rp internal thread Quick opening, quick closing Mains voltage: 120 V
88033512
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 40 (1 1/2'') Outlet: DN 40 (1 1/2'') NPT internal thread Quick opening, quick closing Mains voltage
88033513
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 2 Also UL listed Inlet: DN 50 (2'') Outlet: DN 50 (2'') NPT internal thread Quick opening, quick closing Mains voltage: 24 V D
88033623
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 15 (1/2'') Outlet: DN 15 (1/2'') Rp internal thread Quick opening, quick closing Mains voltage: 230 V
88033717
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 EU certified Inlet: DN 20 (3/4'') Outlet: DN 20 (3/4'') Rp internal thread Quick opening, quick closing Mains voltage: 24 V
88033880
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 25 (1'') Outlet: DN 25 (1'') NPT internal thread Quick opening, quick closing Mains voltage: 24 V D
88033881
For gas, air and biologically produced methane, pu max. 500 mbar (7 psig), with pilot lamp, IP 65, FM and CSA approved Size 1 Also UL listed Inlet: DN 25 (1'') Outlet: DN 25 (1'') NPT internal thread Quick opening, quick closing Mains voltage: 24 V D

Get in touch